Edit documentation Edit document
Automation Nodes

Constants

Constants is an automation node that allows to create static templates or constant values for using in other nodes. You can enter, save, and edit any data in constant settings. For example, you can use it in conjunction with the Message Constructor. The Constants is usually used for saving the templates of messages. After transmitting, that templates will be filled with values in Message Constructor.

Node for creating constants

Inputs

The current node has only one input node, the accepted value of which is not used in the creation of templates.

Default Input Sockets

The current node has no default input sockets.

Additional Input Sockets

The current node has only one input socket. It is available when the Send Constant By is PUSH. The push socket is designed to delay the operation of the node until a certain value is transmitted to it.

Name Data Type Description
PUSH value accepted value will be the trigger to start the node operation

Outputs

The Constants node do not have any default output sockets, but it have settings which allows it to add unlimited number of additional socket.

Default Output Sockets

As in the case of input sockets, there are no output sockets by default in this node.

Additional Output Sockets

The current node can have many output sockets. The number of such socket is depended of the number of constants in Value Outputs Table. Each of these sockets transmits the corresponding constant value.

Options

The current node has two block of settings.

Value Outputs

The first block of settings only configures the start time of the node.

Value Outputs

Name Description
Send Constant By allows to select the type of node operation; details...
Notes allows to note the needed info about settings; details...

Send Constant By

The current option allows you to configure the start of the node. Namely, you can delay the operation of the node by selecting the PUSH button until some value is transferred to the node. Or you can leave it to work in normal mode using the PULL button, that is, the node will start working immediately after the automation is activated.

Notes

Use this field to leave any notes in the settings of the node.

Value Outputs Table

The second block is designed to add, update and delete constants.

Settings of value outputs

Name Description
Constant Name allows to enter constant name; details...
Constant Value allows to enter the value of the constants; details...
Edit allows to edit or delete the constant; details...

Constant Name

This is the name of the constant that is used in other nodes to transmit the constant value. It is also used as a name of the output socket.

Constant Value

This function allows you to enter and view the value of a constant. After clicking on it, the working entry field opens. If the constant already has a value, it will be displayed there.

Edit

This option has two buttons to edit and delete the constant.